GIM38201E/GIM31901I on Usermod during Apply Check
search cancel

GIM38201E/GIM31901I on Usermod during Apply Check

book

Article ID: 273149

calendar_today

Updated On:

Products

Endevor

Issue/Introduction

During the Apply Check for USRMODB, the following errors are generated. What is the recommended action for this error?

GIM38201E ** THERE IS A MODID ERROR FOR SRC ENTRY BC1TNEQU IN SYSMOD USRMODB.                                           
GIM31901I    SYSMOD USRMODB DOES NOT SPECIFY LU08317 ON THE PRE OR SUP OPERAND. LU08317 IS THE RMID FOR SRC BC1TNEQU    
              THAT IS CURRENTLY INSTALLED.                                                                               
GIM22601I    APPLY PROCESSING FAILED FOR SYSMOD USRMODB. 

 

 

Environment

Release : 19.0

Resolution

There are two options to navigate around this error - add a PRE(LU08317) to USRMODB or use BYPASS(ID).  