Automic System outage due to (U00009907 Memory view 'Parameter List)
search cancel

Automic System outage due to (U00009907 Memory view 'Parameter List)

book

Article ID: 273026

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Automic Automation System moved to unresponsive state due to high PWP (MQ1PWP) Count and the only option to bring it back online to perform the COLD start of the AE Engine.

U00011860 Deleting Agent entry 'AGENT-TEST' with index '0000001885'.

Access violation at 00007FF9EE3AA4A3 on read XXXXXXXXXX

U00009907 Memory view 'Parameter List ' (Address='XXXXXXXX', Length='1296')

00000000  25255352 30310400 00000000 20202020  >%%XXXXX......    <

00000010= 20202020 20202020 20202020 20202020  >                <

00000400  20202020 20202020 20202020 00800200  >           .<

00000410  6C070000 E8730200 E08E6200 48081F00  >

0000420  2A534552 56455220 20202020 20202020  >*SERVER XXXX        <

00000430  20202020 20202020 20202020 20202020  >                <

Environment

Release : Automic.Automation 21.0.5+hf.2

Cause

The problem is related to the timing as WP sends FTXSEND to Agent1:

Automation Engine can crash during starting of a file transfer on a SRC agent which is not reachable at this moment.

Resolution

The defect opened for the problem mentioned here has been resolved and will be part of below releases.


Fix Versions: Automation.Engine 24.0.0,
                      Automation.Engine 21.0.8