RRSAF CAS9 INIT failed with CAMS911E CAMS913E as per LU07904
search cancel

RRSAF CAS9 INIT failed with CAMS911E CAMS913E as per LU07904

book

Article ID: 271207

calendar_today

Updated On:

Products

Smart RRSAF

Issue/Introduction

The CAS9 job fails with;

CAMS911E KEYWORD ROUTINE IS REQUIRED BUT WAS NOT SPECIFIED
CAMS913E KEYWORD ................................ IS UNREC
CAS9140E - INIT ERROR: RAIPRODUCTS          VER 7P20, INIT
CAS9115I - INPUT: LOADLIB(SYSV.CAI.RRSAF.CRAILOAD) PARM(RO
CAS9140E - INIT ERROR:                      VER     , PARA

Trying to resolve HOLDDATA for PTF LU07904.

Resolution

The syntax should be:

PRODUCT(RAI PRODUCTS) VERSION(7P20) INIT(RAIPCDEF)                    -
LOADLIB(?raihlq?.CRAILOAD) PARM(ROUTINE=RAIPCSS1,REINIT)

The syntax is missing the continuation hyphen on the end of the first line.
Once added that resolved the problem.