Having changed the length of a compressed segment, a reload of the database using the new DBD is failing with the following errors:
+SHR015I segment REC DEFS IMPLY WRONG LENGTH
+SHR309I segment CHECK BYTE MISMATCH
+SHR320I - SEGM segment. SHRINK OR EXPAND ERROR
USER COMPLETION CODE=3993
TIME=10.27.35 SEQ=21586 CPU=0000 ASID=00D4
PSW AT TIME OF ERROR 078D1000 981F3376 ILC 2 INTC 0D
ACTIVE MODULE ADDRESS=00000000_181F3350 OFFSET=00000026
NAME=IMTTSHRN
Release : 20.0
This combination of +SHR messages indicates a potential mismatch between the DBD and the FDT.
You must create a new FDT for the new (changed) DBD. The new FDT must then be used together with the new DBD for the reload.
Please refer to the documentation for the IMSPASS Utility for further details.