An IMS MPP region received a S0F8 abend. The region was restarted successfully. The IMS systems programmer opened an PMR with IBM. The dump indicates the abending program is WARPPCR4.
.
Abend Code = S0F8 - 10
Abend Location (APSW): Primary-space mode, Supervisor state, Key 7
PSW = 077C0000 80AE8098 Data at PSW-6 = F0001B110A08 184041700003
WARPPCR4+0098
The PSW points to the dump eyecatcher, to this OEM module:
| .00<WARPPCR4 V20 |
| 0 02/02/12 15. |
| 36 COPYRIGHT P |
| LATINUM TECHNOLO |
| GY 1999 .00. |
| ..-.. .\.00&...{ |
| .........&..Dm.r |
| ..B<....N.&.E.. |
.
Z/OS
IMS
Date Simulator's WARPIMS utility was executed simultaneously with the IMS MPP region initialization. This led to Date Simulator hook being installed while the IMS MPP region was still initializing.
1) Modify the IMS startup to not execute WARPIMS or WARPPARM utility.
2) Run the WARPIMS and WARPPARM utility once IMS startup of all dependent regions have completed initialization.