Issue/Introduction

The Encore Sanity report shows errors below, and the user wants to know how to clear them:

***     Job TEST   (J0033784) has an invalid record header in slot number 360556
 CYB633E Invalid record header encountered, Slot 360542 
 *** ERROR 24 while Reading record 360542 ***
....
 =====================================
 EXECUTION HISTORY FILE ERROR SUMMARY:
 =====================================

         Number of lost slots:                   480     (Cond Code 0004)
         Number of incorrect index pointers:       0     (Cond Code 0008)
         Number of bad file record headers:       53     (Cond Code 0012)
......
         Number of broken-record-queue errors:     2     (Cond Code 0048)

Environment

Release : 12.0
Component: Encore

Resolution

The errors "broken-record-queue errors" can be cleared by CYBRMPRG with JOB=TEST specified.

And the "bad file record headers" errors should go away after next CYBRMPRG run.

Follow the steps in the doc link below to remove the lost slots:
https://techdocs.broadcom.com/us/en/ca-mainframe-software/automation/ca-workload-automation-esp-edition/12-0/programming/use-utilities/cybrmsan-monitor-exh-errors-and-reclaim-slots.html

CYBRMSAN can remove lost slots from the EXH data set. The utility must have exclusive write access to the EXH data set to repair it. The following procedure shows you how to remove lost slots:
1. Issue the ENCPARM QUIESCE command on all subsystems using the EXH data set you want to remove lost slots from.
2. In the EXH DD statement of the utility JCL, change DISP=SHR to DISP=OLD.
3. Run the CYBRMSAN utility.
4. Issue the ENCPARM RESTART command on all subsystems using the EXH data set you want to remove lost slots from.