Bringing up Sysview 17.0 for the first time, and getting GSV2565E System configuration member <member> contains no options.
search cancel

Bringing up Sysview 17.0 for the first time, and getting GSV2565E System configuration member <member> contains no options.

book

Article ID: 268540

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

Bringing up Sysview 17.0 for the first time, and getting GSV2565E System configuration member <member> contains no options.

Environment

Release : 17.0

Cause

Potential mismatched load modules

Resolution

The messages occurred immediately upon startup.   The most likely cause of this is having an older copy of modules in the LOADLIB.   Any loadlibs that show up in the STC concatenation messages should be checked, especially in the event where the library name is not release specific.

Some customers may have a release check coded in their OPTIONS member, and if so, then they can comment out the line )IF RELEASE=17.0  in the GSVWGXVX and see if the task gets any further in its startup.