Issue/Introduction

Since applying the new Levelset63A z/OS2.5 upgrade with maintenance drops on BMC and Broadcom software error messages below appear in some of the jobs:

XPEDITER/TSO SVC 42 ATTACH PREVIOUS DEQ FAILURE DETECTED
XPEDITER/TSO SVC 42 ATTACH PREVIOUS DEQ FAILURE DETECTED
XPEDITER/TSO SVC 42 ATTACH PREVIOUS DEQ FAILURE DETECTED
XPEDITER/TSO SVC 42 ATTACH PREVIOUS DEQ FAILURE DETECTED
XPEDITER/TSO SVC 42 ATTACH SVC ENQ FAILURE          RC=16
XPEDITER/TSO SVC 42 ATTACH PREVIOUS DEQ FAILURE DETECTED
XPEDITER/TSO SVC 42 ATTACH SVC ENQ FAILURE          RC=16

CCSR061I PSW: 00000000 00000000 070C2000 814B382E        
CAS9331I - SVC dump for task CAS9EVNP captured          
CCSR060I BREAKING EVENT ADDRESS: 00000000 014B37D4      
CCSR061I PSW: 07042000 80000000 00000000 014B382E       
CCSR062I ILC: 04 INTERRUPT CODE: 30                     
CCSR067I COMPLETION CODE S0E0 REASON CODE 00000030

The SVC dumps were seen in task CAIENF (Broadcom Common Services)

QEOS 21.09.47 STC34513  IEA794I SVC DUMP HAS CAPTURED:  675                         
   675             DUMPID=001 REQUESTED BY JOB (jobname)                      
   675             DUMP TITLE=COMPID=CAENF,ISSUER=CAS9DUMP,MODULE=NONE,ABEND=S0E
   675                        REASON=00000030

The jobs appear to complete and are not required to be restarted/reran. No obvious impact noted.

Environment

Release : 15.0

Resolution

ENF is only the victim.

The dump shows the problem is that some SSI hook is driving code that issues a WTO, which in turn drives the SSI hooks which turn turn issues a WTO which drives the SSI hooks, etc...(recursion).

The WTO being issued(recursively) is: 

XPEDITER/TSO SVC 42 ATTACH PREVIOUS DEQ FAILURE DETECTED

It is being issued from what appears to be BMC Xpeditor module: XPMSVC42

BMC have confirmed the problem to be caused by their product Xpeditor/TSO. 

BMC has fixed the problem in Xpediter/TSO 17.2  PTF XTN199A.
Since the change of product name it's recommend to apply the PTF XTN200A (which includes XTN199A). 
And - be aware of the HOLDDATA for this PTF ..