When changing status report from 4 columns to 6 it does not save the setting after publishing, leaving and come back into the project and view the status report, it always reverts back to 4 columns.
Steps to Rerpoduce
1- Log in to Clarity MUX
2- Open project
3- Go to Status Module
4- Change the view
5- Click 'Configure'
6- Click 'Layout'
7- Change layout 4-Columns > 6-Columns
8- Resize widgets so that they take up 6-Columns
9 -Click 'Done' and Save the View
10- Click 'Preview' and 'Publish' to validate 6-Column layout and close
11- Click 'Configure' again
12- Reconfigure or make change to any of the widget, click 'Done' and Save the View
13- Click 'Preview' again
Expected Results: The view and the preview layouts match
Actual Results: The layouts are not the same
Workaround: User will have to avoid changing the layout.
Release : 16.1.1
DE69648, Fixed in 16.1.2. When the layout is changed, in memory data was not updated with the column count. So, any new view created was created with the old column count. Fix is made to keep the in memory count in sync.