Subsystem Analyzer stopped collecting and now it will not start and returns 'SA036E: Datastore name does not exist'.
search cancel

Subsystem Analyzer stopped collecting and now it will not start and returns 'SA036E: Datastore name does not exist'.

book

Article ID: 263481

calendar_today

Updated On:

Products

Database Management for DB2 for z/OS - Administration Suite Database Management for DB2 for z/OS - Performance Suite Database Management for DB2 for z/OS - Recovery Suite Database Management for DB2 for z/OS - SQL Performance Suite Database Management for DB2 for z/OS - Utilities Suite

Issue/Introduction

Subsystem Analyzer stopped collecting and repeatedly issued message

05:00:56  MIM1038I XMAN52 JOB91716 A=0130 T=9BA1E0 contention with XMAN52 A=0130 T=9B09D8 OWNS EXCL on SY52
05:00:56  MIM1039I XMAN52 JOB91716 A=0130 T=9BA1E0 needs EXCL CADB2 OLDB.DB2.XMAN51.SUBSYS.R15.

SA036E: Datastore name does not exist, however datastore does exist.  

 

 

Environment

Release : 20.0

Resolution

Creating a new datastore resolved the problem.