Issue/Introduction

Trying to configure OI connector in new 10.8 environment.

We are getting several error messages that may or may not pertain to the integration configuration.

Environment

Release : 10.8

Resolution

Once on-premise 10.8 APM cluster integration is complete with DX SAAS, we need the following configuration to send data (metrics) to DX SAAS. 

We need Management Module on collectors.

The metric are sent directly from the Collectors thus every collector has to have configured connectivity to DX SAAS OI, and the metric group//Management Module configuration on collectors are required.

One easy way may be to configure the Management Module on MOM. Once test and validation is complete, we can simply move the Management  Module to collectors.

You can move the Management  Module jar file under <EM-HOME>/config/modules and restart the collector EM.