CDM DISK I/O showing wrong output on RHEL8.6 version
search cancel

CDM DISK I/O showing wrong output on RHEL8.6 version

book

Article ID: 262593

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

We have found since upgrading some servers to RedHat Enterprise Linux 8.6 or higher we are getting the wrong results for disk I/O which is causing false alarms.

The metrics for IOSTAT are showing above 300 to 400% while previously these machines always showed single-digit values.

 

Environment

Release : 20.4

Cause

The following command is used by CDM to retrieve the iostat details:

iostat -d -x -k 10 2

In RedHat 8.6 and above the output of this command has changed to include additional columns which affects the parsing of the output.

Resolution

A new CDM probe build will be released (tenative ETA - April 15 2023) which resolves this issue.

The current release of CDM (6.84) and prior versions are affected.

 

Additional Information

If the situation is urgent, a test build may be downloaded which resolves the issue - it is attached to this article.  (cdm 6.84-T1-build7)

Attachments

cdm-6.84-T1-build7_1679580637611.zip get_app