GSVX434W warnings in STC after upgrading to SYSVIEW 17.0
search cancel

GSVX434W warnings in STC after upgrading to SYSVIEW 17.0

book

Article ID: 261400

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

After upgrading to SYSVIEW 17.0 many GSVX434W messages appear in the STC log.  Such as:

 
GSVX434W (CICSDATA) Member CICSDATA - Diagnostic configuration option VARIABLE-SET is in use.  
 
Value      CICS:=_______:ENABLED                                                                    
 
GSVX449I (CICSDATA) Collection metric CICS = ENABLED                                                     
 
GSVX434W (CICSDATA) Member CICSDATA - Diagnostic configuration option VARIABLE-SET is in use.
 
Value      CICS:=_______:NOTSD                                                                        
 
GSVX449I (CICSDATA) Collection metric CICS = NOTSD                                                       
 
GSVX434W (MQSDATA) Member MQSDATA - Diagnostic configuration option VARIABLE-SET is in use.
 
Value WEBMQ:=:ENABLE 
 
GSVX449I (MQSDATA) Collection metric WEBMQ = ENABLED                                                             
 
GSVX434W (MQSDATA) Member MQSDATA - Diagnostic configuration option VARIABLE-SET is in use.
 
Value WEBMQ:=:NOTSD  
 
GSVX449I (MQSDATA) Collection metric WEBMQ = NOTSD                                                               
 
GSVX434W (MVSDATA) Member MVSDATA - Diagnostic configuration option VARIABLE-SET is in use.
 
Value MVS:=:ENABLE   
 
GSVX449I (MVSDATA) Collection metric MVS = ENABLED                                                               
 
GSVX434W (MVSDATA) Member MVSDATA - Diagnostic configuration option VARIABLE-SET is in use.
 
Value                MVS:JOBALL%_:ENABLE

Environment

Release : 17.0

Cause

The parmlib member MQSVARS contained statements from the previous release.

Resolution

The following changed in the MQSVARS parmlib member in SYSVIEW 17.0:
 
 
VARIABLE-SET      WEBMQ:xxxxx
 
        was changed to 

METRIC-SET         MQ:xxxxx
 
 
Check both the SITE and SYSTEM CNM4BPRM library MQSVARS member for "VARIABLE-SET".   If found, change it to
 
METRIC-SET.
 
Once the syntax is changed, SYSVIEW 17.0 should come up without the GSVX434W messages.  
-
 
 
Note:  The same would be true for any other xxxxVARS members SYSVIEW has.