Upgrade package error: update script error -1: create
search cancel

Upgrade package error: update script error -1: create

book

Article ID: 261219

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

During upgrading DUAS via unipkg we can see an error message:

| 2023-02-23 10:47:14 |INFO |X|IO |pid=3032.11712| u_io_thread_auto_update   | Launching DUAS-UPDATE-WINDOWS64-6.10.102 update: C:\Program Files\AUTOMIC\DUAS\COMPANY_NODE\temp\uniupdate.bat
| 2023-02-23 10:47:14 |ERROR|X|IO |pid=3032.11712| u_io_thread_auto_update   | update script error -1: create("C:\Program Files\AUTOMIC\DUAS\COMPANY_NODE\temp\uniupdate.bat" U000000002 "DUAS-UPDATE-WINDOWS64-6.10.102" "C:\Program Files\AUTOMIC\DUAS\COMPANY_NODE" "C:\Program Files\AUTOMIC\DUAS\COMPANY_NODE\temp" > "C:\Program Files\AUTOMIC\DUAS\COMPANY_NODE\log\exp\update.log" 2>&1) failed
| 2023-02-23 10:47:31 |INFO |X|IO |pid=3032.4464| u_close_engines           | Stopping BVS...

Environment

Release : 6.x, 7.x

Component. Automic Dollar Universe

Cause

Defect

Resolution

The error message does not affect the Dollar Universe update and can be ignored. It is related to the timeout set to 1 millisecond. This is the same layer that is used to execute this script than any other windows process (the script is supposed to stop $U so we don't want to wait and block it).

This bug will be fixed in one of the next DUAS releases.