Attempting to implement RAI Smart/RESTART PC routine and receiving the following:

Syntax:
PRODUCT(RAI PRODUCTS) VERSION(7P20) INIT(RAIPCDEF) -
LOADLIB(xxx.xxxxxxxx.xxxxxx) PARM(ROUTINE-RAIPCSS1,REINIT)


Error messages:
IEF196I CAS9115I - Input: PRODUCT(RAIPRODUCTS) VERSION(7P20)
IEF196I INIT(RAIPCDEF) LOADLIB(DB
*CAMS911E KEYWORD ROUTINE IS REQUIRED BUT WAS NOT SPECIFIED 333
*CAMS913E KEYWORD ROUTINE-RAIPCSS1 IS UNRECOGNIZED 335
CAS9140E - Init error: RAIPRODUCTS          Ver 7P20, Init routine RC=0010

Resolution

From the posted syntax the following syntax appears to be specified:
PARM(ROUTINE-RAIPCSS1,REINIT)

This should be the following with an equals (=) sign after ROUTINE:
PARM(ROUTINE=RAIPCSS1,REINIT)