ARA Upgrade Problems to version 11.0.4 with the Ramiustool 11.0.0
search cancel

ARA Upgrade Problems to version 11.0.4 with the Ramiustool 11.0.0

book

Article ID: 260626

calendar_today

Updated On:

Products

CA Continuous Delivery Automation - Automation Engine

Issue/Introduction

Upgrade a CDA environment with the RAMIUS Tool runs in different errors.

Finally the updated CDA 11.0.4 is stucked and doe snot start.

Extracted from the Log.txt of the updated CDA implementation:

======================================================

CustomerAppSettings section:

    Database.Type=ORACLE
    ReportDatabase.Type=ORACLE
    InternalAuthentication=enabled
    UC4Deployment.ECCURL=https://rb-eut1.bosch.com/awi
    UC4Deployment.CallbackUrl=https://si0vm2256.de.bosch.com:443/ara
    AutomationEngine.Timeout=300
    AutomationEngine.TraceLevel=9
    Configuration.RefreshCycleInSeconds=600

2023-01-30 08:56:50,732 \[1\] INFO  operationLog - .NET Framework version: 4.7.2
2023-01-30 08:56:50,749 \[1\] INFO  operationLog - \----------------------------SYSTEM STARTED---------------------------\-
2023-01-30 08:56:50,749 \[1\] INFO  operationLog - SYSTEM STATUS: NotSetup
2023-01-30 08:56:52,513 \[1\] INFO  Wiring - Initialization completed. Time taken 137.6394
2023-01-30 08:58:40,328 \[15\] WARN  SYSTEM \- 

\----------------------------SYSTEM SHUTDOWN---------------------------\-
Shutdown Message: HostingEnvironment initiated shutdown
HostingEnvironment caused shutdown

======================================================

 

Environment

Source CDA version 10.0.9 HF1
Target CDA version 11.0.4+build.1661252700839
AWI/AE 21.0.4 HF1 Ramius tool : 11.0.0

Cause

This is a defect of the CDA application. Prior to version 11.0.5

Resolution

Resolution: 

This bug is fixed in CDA 11.0.5 available since12.02.2023.

Use CDA 11.0.5 and the shipped in version of the RAMIUS-tool to peform the requested upgrade.