Upgrade a CDA environment with the RAMIUS Tool runs in different errors.
Finally the updated CDA 11.0.4 is stucked and doe snot start.
Extracted from the Log.txt of the updated CDA implementation:
======================================================
CustomerAppSettings section:
Database.Type=ORACLE
ReportDatabase.Type=ORACLE
InternalAuthentication=enabled
UC4Deployment.ECCURL=https://rb-eut1.bosch.com/awi
UC4Deployment.CallbackUrl=https://si0vm2256.de.bosch.com:443/ara
AutomationEngine.Timeout=300
AutomationEngine.TraceLevel=9
Configuration.RefreshCycleInSeconds=600
2023-01-30 08:56:50,732 \[1\] INFO operationLog - .NET Framework version: 4.7.2
2023-01-30 08:56:50,749 \[1\] INFO operationLog - \----------------------------SYSTEM STARTED---------------------------\-
2023-01-30 08:56:50,749 \[1\] INFO operationLog - SYSTEM STATUS: NotSetup
2023-01-30 08:56:52,513 \[1\] INFO Wiring - Initialization completed. Time taken 137.6394
2023-01-30 08:58:40,328 \[15\] WARN SYSTEM \-
\----------------------------SYSTEM SHUTDOWN---------------------------\-
Shutdown Message: HostingEnvironment initiated shutdown
HostingEnvironment caused shutdown
======================================================
Source CDA version 10.0.9 HF1
Target CDA version 11.0.4+build.1661252700839
AWI/AE 21.0.4 HF1 Ramius tool : 11.0.0
This is a defect of the CDA application. Prior to version 11.0.5
Resolution:
This bug is fixed in CDA 11.0.5 available since12.02.2023.
Use CDA 11.0.5 and the shipped in version of the RAMIUS-tool to peform the requested upgrade.