Job abended with an IEC146I 513-04,IFG0194A
search cancel

Job abended with an IEC146I 513-04,IFG0194A

book

Article ID: 260497

calendar_today

Updated On:

Products

CA 1 Flexible Storage

Issue/Introduction

One of our database jobs abended with an

IEC146I 513-04,IFG0194A,PJOB,TRAN,DDOUPUT,1088,vvvvvv,  dataset name output                                                                     
                                       
 23.40.09 J0003704  IEA995I SYMPTOM DUMP OUTPUT  608                                                                                 
    608             SYSTEM COMPLETION CODE=513  REASON CODE=00000004                                                                 
    608              TIME=23.40.06  SEQ=16500  CPU=0000  ASID=023A                                                                   
    608              PSW AT TIME OF ERROR  075C1000   80EB170C  ILC 2  INTC 0D                                                       
    608                NO ACTIVE MODULE FOUND                                                                                        
    608                NAME=UNKNOWN                                                                                                  
    608                DATA AT PSW  00EB1706 - 4100302C  0A0D010D  A7E5014B                                                          
    608                AR/GR 0: 009F8238/00EB1A14   1: 00000000/A4513000                                                             
    608                      2: 00000000/000F8CA8   3: 00000000/00EB19E8                                                             
    608                      4: 00000000/009B94D8   5: 00000000/009BB7A4                                                             
    608                      6: 00000000/009BB74C   7: 00000000/009BB7A4                                                             
    608                      8: 00000000/009BB76C   9: 00000000/009BB520                                                             
    608                      A: 00000000/009C3D40   B: 00000000/7FF5BCE8                                                             
    608                      C: 00000000/80EB4A76   D: 00000000/7FF5BCE8                                                             
    608                      E: 00000000/80EB0F6A   F: 00000000/00000004                                                             
    608              END OF SYMPTOM DUMP                                                                                             
 IEFTMS50 1XX- 08 DBJOB,TRAN    ,DDOUTPUT ,2088,699999,00001,data set name output,TMC=                             
 IEFTMS50 ***** CA 1 ABEND,CL,68 *****                  **                S513-04. for the output. volume.

Environment

Release : 14.0

Cause

The application is trying to open a volume that is still open.

Resolution

IEC146I 513-04 means
"An OPEN macro instruction was issued for a magnetic tape data set allocated to a device that already has an open data set on it. Make sure that the first data set is closed before the second is opened, or allocate the second data set to a different device. This error may be due to a previous abnormal end associated with the same unit in the same step. If so, correct the error causing the previous abnormal end."

Problem:
As per the above message, you are trying to open the dataset for two different purposes in the same job step. You should check with the application. vendor to verify the open of the output volume.