OPSMAIN is abending with code S0C4 at startup after the upgrade from release 13.0 to 14.0.
OPS3092H OPS/REXX ABEND 000C4000 DETECTED AT OPRXDY + 271A8248
OPS3092H PSW AT ABEND 078D1000DD4F0328 - DATA AT PSW IS NOT ACCESSIBLE
OPS3092H LAST PRB PSW 078D1000DD4F0328 - DATA AT PSW IS NOT ACCESSIBLE
OPS3092H TRANSLATION EXCEPTION ADDRESS ===> 5D4F0800
OPS3092H HOME ASID 0107 PRIMARY ASID 0107 SECONDARY ASID 0107
OPS3092H ABEND INTERRUPT CODE 0010 ABEND REASON CODE 00000010
OPS3092H R0=B5FD9090 OPDS +08B8 C5D5E5C2 D3D6C3D2 F0F1F0F0 00000140
...
OPS3092H ACCESS REGISTERS AT TIME OF ABEND:
OPS3092H AR0=00000000 AR1=00000000 AR2=00000000 AR3=00000000
OPS3092H AR4=00000000 AR5=00000000 AR6=00000000 AR7=00000000
OPS3092H AR8=00000000 AR9=00000000 AR10=00000000 AR11=00000000
OPS3092H AR12=00000000 AR13=00000000 AR14=00000000 AR15=00000000
OPS3092H ERROR 49 RUNNING OPDYRLIN, LINE 133: INTERPRETATION ERROR
Release : 14.0
This problem was caused by the presence of an OPS 13.0 load library in the LNKLST. Although the OPS started tasks had STEPLIB pointed to the OPS 14.0 load library a 13.0 module may be referenced if present in the LNKLST
Remove the OPS 13.0 (or any release older than 14.0) from LNKLST and restart OPSMAIN