When trying to run the EARL reports using the panels supplied with ACF2, all the fields are updated with the report, and then the following error is seen: ERROR CALLING CA-EARL
When pressing PF1 for HELP, this error is seen: ENSURE CLIST ACFFLT# HAS CORRECT DEFAULTS
What do needs to be done?
The CLIST library supplied with ACF2 (library ACF2.CAX1CLS0 in r15 and r16) contains member ACFFLT#. Early in the CLIST is a line with:
PGMLIB(CAI.EARL.CXO60LLD).
This (PGMLIB) library name needs to be modified to reflect the library that contain the EARL program installed with CA Common Services. The default library for CA Common Services is CAI.CCCSLOAD. Verify that the program EARL exists in this library. If it is not there, then check with the system programmer that installed CA Common Services to see if and where EARL was installed. The CA EARL FMID is CXE6100. This CA Common Services component must be installed before running any of the EARL reports for CA-ACF2.