OLQ 098012 08 Sort error number: 33 - PUT SCRATCH ERROR-SIGNON TO DC AGAIN
search cancel

OLQ 098012 08 Sort error number: 33 - PUT SCRATCH ERROR-SIGNON TO DC AGAIN

book

Article ID: 258236

calendar_today

Updated On:

Products

IDMS

Issue/Introduction

The OLQBATCH job ran out of scratch processing a very large SORT.and failed with error messages: 

OLQ 098012 08  Sort error number: 33 - PUT SCRATCH ERROR-SIGNON TO DC AGAIN  
OLQ 090017 08  Unable to process Select request due to record build error

 

Environment

Release : 19.0

Resolution

 

To increase the amount of scratch available to the OLQBATCH job:

1. Add the following  SYSIDMS parameters to you the OLQBATCH JCL

SCRATCH_IN_STORAGE=ANY                              

SCRATCH_PRIMARY_EXTENT=20MB                        
SCRATCH_SECONDARY_EXTENT=20MB            

2. Ensure the OLQBATCH JOB has a REGION= size specified that is large enough to be able to accommodate (we recommend REGION=0M).

For example:

//OLQBATCH EXEC PGM=OLQBATCH,REGION=0M
       
  ...
//SYSIDMS  DD *                                      
SCRATCH_IN_STORAGE=ANY                              
SCRATCH_PRIMARY_EXTENT=20MB                        
SCRATCH_SECONDARY_EXTENT=20MB                      
DMCL=DMCL1900                                      
//SYSIPT   DD *
...

 

 

 

Additional Information

IDMS™ 19.0 - SYSIDMS Parameter Descriptions