IPL Fails with S0C4 in CSVSBRTN +2302
search cancel

IPL Fails with S0C4 in CSVSBRTN +2302

book

Article ID: 257817

calendar_today

Updated On:

Products

COMMON SERVICES FOR Z/OS

Issue/Introduction

IPL Fails with an S0C4 abend in CSVSBRTN +2302. Issues Loading a Module During IPL.

Occurs while executing the routine CsvfetchExit_Fetch with the input CDE, created for module ICHSEC05.

The CDE  was obtained in module CCSEFXSR, and built incorrectly, it has the bit CDCDEX on but no extension exists.

 

Environment

Release : 15.0

Cause

The CCSEFXSR module from the dump shows it's for Common Services 14.0 not 15.0.

This is caused by an incorrect old release library in the LPA and loading an old version of CCSEFXSR. 

Resolution

The module CCSEFXSR  resides in the CAW0LPA library.

Check for an old Common Services 14.0 library in the LPA library list.