IBM Fault AnaIyzer Problem after applying Top Secret PTFs
search cancel

IBM Fault AnaIyzer Problem after applying Top Secret PTFs

book

Article ID: 256689

calendar_today

Updated On:

Products

Top Secret

Issue/Introduction

IBM Fault Analyzer abends after applying several Top Secret PTFs.

The error received is:

IDI0065W CICS Exit SVC KEY8 MVS_ATTACH failed. Return code=FD7BE8     

 

After fallback to the older TSS ptf level the problem is not happening.

 

The PTFS applied are:

 

LU05554 - CPF RECOVERY RECORDS ARE NOT CLEANED UP FROM CPFFILE
LU06640 - INCORRECT RETURN CODE ON RACROUTE VERIFY WITH SERVAUTH
LU06987 - TSSCFBK PRODUCES UNKNOWN DATA ENCOUNTERED MSGS WITH LU06089
LU07029 - MFA USER GETTING SUSPENDED WITHOUT PASSWORD IN CICS
LU07164 - ATTACH PROGRAM SECURITY BYPASSED WITH BMC BATCH OPTIMIZER
LU07457 - CICS ADDRESS SPACE ABENDS DUE TO X'15'S OVERLAY WITH LU02328
LU07505 - AUDIT TASK FAILS TO RELEASE LOCK DURING ABEND RECOVERY
LU07536 - SUPPORT THE USE OF UNIX SYSTEM SERVICES BY THE MSCA
LU07548 - CICS U0997 ABEND DURING START UP
LU07737 - SECURITY OR INTEGRITY PROBLEM

 

Environment

Release : 16.0

Cause

LU07737 is in error

 

Resolution

Apply LU07783