"CreateProcess failed ==> %1 is not a valid Win32 application." reported when installing Unicenter Workload Control Center
book
Article ID: 25665
calendar_today
Updated On:
Products
CA Workload Automation AE - Business Agents (AutoSys)CA Workload Automation AE - Scheduler (AutoSys)Workload Automation AgentCA Directory
Issue/Introduction
When running setupwin32.exe to install the Unicenter Workload Control Center, I receive the following error:
"CreateProcess failed ==> %1 is not a valid Win32 application."
Resolution
This error could be a result of the Windows environment variable TEMP being set to a value unknown to the ISMP installer (in this case the value was %TEMP%).
To correct this value:
Start -> Settings -> Control Panel -> System -> Advanced -> Environmental Variables.
Set the value for TEMP to a real directory on the machine: