After a successful upgrade of UIM using the "silent install" method, one or more probes are in a deactivated (gray) state.
The probe versions appear to have been successfully upgraded and no errors are seen in the installation log.
Release :
This issue has been seen with DX UIM 20.3 upgrading to 20.4, and also upgrading from 20.4 GA to 20.4 CU10 but it could impact other versions.
Unknown
This issue has not been seen frequently but in each case observed so far, the probes could all be started manually without error.
Activate these probes first in the following order:
distsrv
data_engine
alarm_enrichment
nas
ems
After this you may start the remaining probes in any order.