We are using spectrumgtw probe to integrate UIM and spectrum. In the UIM alarm filter configuration it is possible to filter which alarms to send to spectrum.
However, only five attributes can be selected.
Is it possible to add new attributes to this list, for example "origin" information?
Environment
Release : UIM 20.4 - Spectrumgtw
Cause
Guidance
Resolution
It is possible to add an additional attribute via Raw Configure > Setup > UIMAlarmAttribute
After this the attribute can be selected in the GUI:
This is added:
This was tested to be working on UIM 20.4 CU5 Connected to DX NetOps Spectrum 22.2.3.0.15