Add UIM Alarm Filter attributes to Spectrumgtw Probe
search cancel

Add UIM Alarm Filter attributes to Spectrumgtw Probe

book

Article ID: 254983

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

We are using spectrumgtw probe to integrate UIM and spectrum. In the UIM alarm filter configuration it is possible to filter which alarms to send to spectrum. 

However, only five attributes can be selected.

 

Is it possible to add new attributes to this list,  for example "origin" information? 

 

 

 

Environment

Release : UIM 20.4 - Spectrumgtw

Cause

Guidance

Resolution

It is possible to add an additional attribute via Raw Configure > Setup > UIMAlarmAttribute

 

https://api-broadcom-ca.wolkenservicedesk.com/attachment/get_attachment_content?uniqueFileId=pu6bCObmBeCSxKK27k0o7A==

After this the attribute can be selected in the GUI:

This is added:

https://api-broadcom-ca.wolkenservicedesk.com/attachment/get_attachment_content?uniqueFileId=bsOV9zaB1pDESwHh6RIfFA==

 

This was tested to be working on UIM 20.4 CU5 Connected to DX NetOps Spectrum 22.2.3.0.15