search cancel

Dashboard Designer - Y-Axis not respecting value of 0 (zero)

book

Article ID: 254234

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

I have a dashboard where I have set the Y-axis minimum to "0", but it is not being respected:

 

Environment

Release : 20.4

Resolution

In UIM 20.4CU4 and earlier, the zero is treated as a blank value, and the axis range is calculated automatically based on the min/max range of the QoS being sampled.

To work around this you can set the axis value to -1 instead of 0.

In UIM 20.4CU5 this has been resolved, and 0 is treated as 0 instead of a blank value.

Attachments