Issue/Introduction

After applying SYSVIEW maintenance getting 'SET$011E Invalid FORMAT value - requested format not defined'. Only some userid have this issue.  

 

Environment

Release : 16.0

Cause

Possibly FORMAT not exist or the profile dataset was corrupted

Resolution

The JHELDQUE cmd screen has subscreens for JES2 and JES3 which in total gave 4 SYSVIEW screens and each of it could have separate FORMATS. By default when JHELDQUE is issued it goes to screen JES2. In the current setup, the defined formats were under JES2DET. See the screenshot below. By issuing additional cmd form JHELDQUE screen OPTIONS DETAIL fixed issue. 
In addition to that, we do PROFILE SAVE to override the users that had the issue.