search cancel

"Ready for generation” of a task status after starting a Queue

book

Article ID: 253205

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

An object stays in "Ready for generation" status after starting a queue.

Reproduction steps:

       - client 9998 is up

       - queue is stopped

       - start the JSCH object JSCH.MAINTENANCE -> it goes in "Waiting for queue slot" status

       - start the queue -> it goes in status "Ready for generation" ... and stay in this status.

Environment

Release : 21.x

Component: Automation Engine

Cause

Bug

Resolution

Disable 'WAIT_STATE_RECORDING' within this client.

or

Update to a fix version listed below or a newer version if available.

Fix version:
Component(s): Automation Engine 

Automation.Engine 21.0.5 - Planned Release End of January 2023

Additional Information

Related documentation:

https://docs.automic.com/documentation/webhelp/english/ALL/components/DOCU/21.0.4/Automic%20Automation%20Guides/Content/AWA/Variables/UC_CLIENT_SETTINGS/UC_CLIENT_WAIT_STATE_RECORDING.htm