search cancel

Post-Install Task SSID0000 Job finished with RC=08 in step BINDPKGS with UNSUCCESSFUL BIND error message

book

Article ID: 252924

calendar_today

Updated On:

Products

DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS

Issue/Introduction

The Post-Install Task SSID0000 Job finished with RC=08 in step BINDPKGS and the following UNSUCCESSFUL BIND error message. 

 BIND PACKAGE ( AUTH2000_RCOBJECT  )                                      MEMBER     ( ROACMAT    )                                 
                CURRENTDATA ( NO   )                                           APPLCOMPAT  ( V12R1M500 )       VALIDATE   ( RUN     
)       ISOLATION  ( CS      )       FLAG       ( I       )       RELEASE    ( COMMIT  )       DBPROTOCOL ( DRDA    )       ENCODING
   ( EBCDIC  )       ACTION     ( REPLACE )       EXPLAIN    ( NO      ) ;                                                          
DSNT208I  -DB1X PROGRAM ROACMAT PRECOMPILED WITH INCORRECT LEVEL FOR                                                                
THIS RELEASE                                                                                                                        
DSNT233I  -DB1X UNSUCCESSFUL BIND FOR                                                                                               
           PACKAGE =                                                                                                                
TEST_DB0X.AUTH2000_RCOBJECT.ROACMAT.(CAD200_2017-02-10-18.42.14)  

Environment

Release : 20.0

Resolution

The HLQ.CDBADBRM(ROACMAT) member was corrupted.

Probably the HLQ.CDBADBRM(ROACMAT) was corrupted after PTF's LU07608 and LU07635 were applied. Checked the *.bin files and the PTF's were already corrupted, so they were possibly corrupted due to a copy. 
  