Switching PTFs from one product to another?
search cancel

Switching PTFs from one product to another?

book

Article ID: 252459

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

My SVWXPTFL looks like this:

CKD1       xxx.xxx.CAI.SV160.CNM4BPRM(SVWXPTFL) - 01.01            Columns 00001 00080
Command ===>                                                          Scroll ===> PAGE
000024 DEFINE
000025    PRODUCT     'SYSVIEW'                                             32
000026    DESCRIPTION 'CA Sysview Performance Management 16.0'              64
000027    FMID        CNM4G00                                                7
000028    XMLLIB      xxx.xxx.CAI.SV160.CNM4XML
000029    CSI         SY.CAI.SV160.CSI
000030    LOADLIB     xxx.xxx.CAI.SV160.CNM4BLOD
000031    MEMBERS     *
000032 ENDDEFINE
000033 DEFINE
000034    PRODUCT     'DATACOM/DB'
000035    DESCRIPTION 'CA Datacom/DB 15.1'
000036    FMID        CABDF10
000037    XMLLIB      xxx.xxx.CAI.DB151.CABDXML
000038    CSI         SY.SMPE.CAI.DB151.CSI
000039    LOADLIB     xxx.xxx.CAI.DB151.DV.CABDLOAD
000040    MEMBERS     *
000041 ENDDEFINE
****** ******************************** Bottom of Data *******************************

When I issue the PTFs command I get a screen that displays SYSVIEW PTFs:

CKD1 EW 16.0 CKD1 --------------------------------- PTFS, Product PTF Analysis -------------------------------- 2022/10/11 15:00:51
Command ====>                                                                                                     Scroll *===> PAGE
-------------------------------------------------------------------------------------------------- Lvl 2 Row 1-15/254 Col 1-131/260
Formats DEFAULT HOLDDATA WARNING
XMLLIB  xxx.xxx.CAI.SV160.CNM4XML
CSI     SY.CAI.SV160.CSI
FMID    CNM4G00
Verify  YES
-----------------------------------------------------------------------------------------------------------------------------------
Cmd      SYSMOD   Type     Description                                                  Status       Published  Applied    Hiper
________ LU06336  DEFECT   SECURITY OR INTEGRITY PROBLEM                                APPLIED      2022/06/23 2022/07/27
________ LU05953  DEFECT   NO SMFDATA COLLECTED BY SYSVIEW W/LU01687                    APPLIED      2022/06/07 2022/07/27
________ LU05614  DEFECT   SECURITY OR INTEGRITY PROBLEM                                APPLIED      2022/04/22 2022/07/27
________ LU04796  DEFECT   ACTSUM ALERTS COMMAND PRODUCES SELE005E SXFT TABLE OVERFLOW  APPLIED      2022/02/18 2022/07/20
________ LU04461  DEFECT   INCORRECT MQ QUEUE DEPTH VALUE FOR SHARED GROUPS             APPLIED      2022/02/08 2022/07/27
________ LU04404  DEFECT   DX APM MVS/IMS METRICS/ALERTS MISSING W/SO15518              APPLIED      2022/01/28 2022/07/27

How do I switch from displaying the product SYSVIEW to displaying DATACOM/DB?  Do I have to know and overtype the CSI and FMID values?

 

Environment

Release : 16.0

Resolution

LU03781 needs to be applied for this functionality to work. The description is as follows:  

After applying the PTF, issue command PTFLIST and based on your SVWPTFL definition there should be at least 2 entries). 
From that screen, issue subcmd in front of the product name and get to MODIDS and CSIQUERY