An A03 abend occurs in the ICL analysis of a RC/Migrator for Db2 for z/OS (RCM) Alter strategy after applying maintenance:
SYSTEM COMPLETION CODE=A03
PSW AT TIME OF ERROR 070C2000 84A7546A ILC 2 INTC 0D
NO ACTIVE MODULE FOUND
NAME=UNKNOWN
DATA AT PSW 04A75464 - 58108010 0A0D58E0 02FC58D0
END OF SYMPTOM DUMP
BPXP018I THREAD 145D480000000000, IN PROCESS 16777656, ENDED 030
WITHOUT BEING UNDUBBED WITH COMPLETION CODE 00A03000
, AND REASON CODE 00000000.
BPXP018I THREAD 145D100000000000, IN PROCESS 50332087, ENDED 031
WITHOUT BEING UNDUBBED WITH COMPLETION CODE 80A03000
, AND REASON CODE 00000000.
The ICL Analysis Report is generated successfully.
PTF LU07096
PTF LU07096 has been placed in error. Fixing PTF LU07459 has been released to address this error.
To resolve this problem either back off PTF LU07096 or apply fixing PTF LU07459.