SA03 and RCM00054 in DDLCOMP step of Database Management Post Install Compare ssid0000
search cancel

SA03 and RCM00054 in DDLCOMP step of Database Management Post Install Compare ssid0000

book

Article ID: 252414

calendar_today

Updated On:

Products

Database Management for DB2 for z/OS - Administration Suite Database Management for DB2 for z/OS - Performance Suite Database Management for DB2 for z/OS - Recovery Suite Database Management for DB2 for z/OS - SQL Performance Suite Database Management for DB2 for z/OS - Utilities Suite DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS

Issue/Introduction

SA03 abend in the DDLCOMP step in Post Install Compare task (ssid0000) after applying maintenance:

SYSTEM COMPLETION CODE=A03 
 PSW AT TIME OF ERROR  070C2000   84A7546A  ILC 2  INTC 0D                                   
   NO ACTIVE MODULE FOUND                                                                    
   NAME=UNKNOWN                                                                              
 DATA AT PSW  04A75464 - 58108010  0A0D58E0  02FC58D0
 END OF SYMPTOM DUMP                                                                         
BPXP018I THREAD 145D480000000000, IN PROCESS 16777656, ENDED  030                            
WITHOUT BEING UNDUBBED WITH COMPLETION CODE 00A03000  
, AND REASON CODE 00000000.       
BPXP018I THREAD 1457180000000001, IN PROCESS 146, ENDED  108
WITHOUT BEING UNDUBBED WITH COMPLETION CODE 80A03000        
, AND REASON CODE 00000000.                                 

RCM00054: RC/Migrator module RML@MAIN has abended.

Cause

PTF LU07096

Resolution

PTF LU07096 has been placed in error. Fixing PTF LU07459 has been released to address this error.