SA03 abend in the DDLCOMP step in Post Install Compare task (ssid0000) after applying maintenance:
SYSTEM COMPLETION CODE=A03
PSW AT TIME OF ERROR 070C2000 84A7546A ILC 2 INTC 0D
NO ACTIVE MODULE FOUND
NAME=UNKNOWN
DATA AT PSW 04A75464 - 58108010 0A0D58E0 02FC58D0
END OF SYMPTOM DUMP
BPXP018I THREAD 145D480000000000, IN PROCESS 16777656, ENDED 030
WITHOUT BEING UNDUBBED WITH COMPLETION CODE 00A03000
, AND REASON CODE 00000000.
BPXP018I THREAD 1457180000000001, IN PROCESS 146, ENDED 108
WITHOUT BEING UNDUBBED WITH COMPLETION CODE 80A03000
, AND REASON CODE 00000000.
RCM00054: RC/Migrator module RML@MAIN has abended.
PTF LU07096
PTF LU07096 has been placed in error. Fixing PTF LU07459 has been released to address this error.
To resolve this problem either back off PTF LU07096 or apply fixing PTF LU07459.