IEC161I 205(050,006,IGG0CLHV)-132,
search cancel

IEC161I 205(050,006,IGG0CLHV)-132,

book

Article ID: 251464

calendar_today

Updated On:

Products

Vantage Storage Resource Manager

Issue/Introduction

 
During the start of vantage 14.1 the following messages are displayed on the STC:
 
IGD17296I DYNAMIC VOLUME COUNT (DVC=8) WAS USED TO  093
EXTEND DATA SET XXXXXXX.XXXX.XXXX.XXXX
IEC161I 205(050,006,IGG0CLHV)-132,SAMS,SAMS,SYS02198,,,  204
IEC161I SYS1.VVDS.VSMPA19
VAN0592E VVDS Error on Vol=SMPA19 - DTOC4VOL VVDS Info Nullified
IEC161I 205(050,006,IGG0CLHV)-132,SAMS,SAMS,SYS02250,,,  254
IEC161I SYS1.VVDS.VSMPB19
VAN0592E VVDS Error on Vol=SMPB19 - DTOC4VOL VVDS Info Nullified
IGD17296I DYNAMIC VOLUME COUNT (DVC=8) WAS USED TO  519
EXTEND DATA SET XXXXXXX.XXXX.XXXX.XXXX

Environment

Release : 14.1

Component : Vantage Storage Resource Manager

Resolution

General Information for Message IEC161I
 
 An error occurred during the processing of an OPEN macro instruction for a
 VSAM data set.  The return code and system actions documented in the
 following text also apply to the CLOSE and EOV messages IEC251I (CLOSE),
 IEC252I (CLOSE TYPE=T), and IEC070I (END OF VOLUME).

 


The DTOC collection was running at time of the problem and Vantage is reading each volume VVDS from the beginning to the end.
That means if a VVDS structur error is detected vantage return the message.

 In this case the messages are all IBM messages and the VVDS seems to have a corrupted record repaired then by the DIAGNOSE.
 So the customer should ask IBM why a dump for CATALOG address space was taken and why the messages ws issued.

Volumes displayed on the VAN0592E messages are skipped in the DTOC processing due to the error detected.