I am trying to start the Spool 14 for the first time and i am receiving the following error;
ESF054 CHKPTDS1 WARM START DENIED, INVALID CHECKPOINT RECORD
ESF002 INITIALIZATION FAILED, CORRECT ABOVE PROBLEMS AND RESTART ESF
Release : 14.0
Component : Spool
Some parameters require a COLD start when changed:
BUFSIZE, CHKPT, MAXFSEQ, NUMFQES,
PGNLEN, SID, SPOOL, SN.
In this particular case, the PGNLEN value had been changed from 20 to 16
PGNLEN=20 <--- 12.0
PGNLEN=16 <--- 14.0
Changing PGNLEN to 20 in the 14.0 parameter solved this problem