Endevor after z/OS 2.5 upgrade getting error "SYM023 POST-PROCESSOR TERMINATED" in PGM IN25COB2
search cancel

Endevor after z/OS 2.5 upgrade getting error "SYM023 POST-PROCESSOR TERMINATED" in PGM IN25COB2

book

Article ID: 251307

calendar_today

Updated On:

Products

Endevor

Issue/Introduction

When running Intertest utility IN25COB2 from an Endevor Processor after upgrading to z/OS 2.5, get  RC 12.  Output is not loading in to protsym file.

 

Get the following message in the JES LOG:

+Non Zero return code from IN25CSTA - exiting

 

The error message in the compile output is:

N25COB2 V11.0 VH00450 - 09/17/2018 03.40                    
                                                             
SYM036 PASSED PARAMETER STATEMENTS                           
                                                             
CB018083,LISTER=ALL,CUTPRINT=ALL                                                                                       
                                                             
SYM010 PROCESSING HAS BEGUN FOR PROGRAM - CB???????           
                                                             
SYM006 LISTER=ALL    REQUESTED                               
SYM007 CUTPRINT=ALL    REQUESTED                             

SYM023 POST-PROCESSOR TERMINATED          

 

      

Environment

Release : 18.0 and 18.1

 

Resolution

1) Ensure Endevor recommended maintenance for z/OS 2.5 has been applied:

V18.0.12 - LU01963

V18.1      - LU01962  

 

2) Verify Intertest V11.0 PTF  LU04390 is also applied. 