When running Intertest utility IN25COB2 from an Endevor Processor after upgrading to z/OS 2.5, get RC 12. Output is not loading in to protsym file.
Get the following message in the JES LOG:
+Non Zero return code from IN25CSTA - exiting
The error message in the compile output is:
N25COB2 V11.0 VH00450 - 09/17/2018 03.40
SYM036 PASSED PARAMETER STATEMENTS
CB018083,LISTER=ALL,CUTPRINT=ALL
SYM010 PROCESSING HAS BEGUN FOR PROGRAM - CB???????
SYM006 LISTER=ALL REQUESTED
SYM007 CUTPRINT=ALL REQUESTED
SYM023 POST-PROCESSOR TERMINATED
Release : 18.0 and 18.1
1) Ensure Endevor recommended maintenance for z/OS 2.5 has been applied:
V18.0.12 - LU01963
V18.1 - LU01962
2) Verify Intertest V11.0 PTF LU04390 is also applied.
See Intertest KB - https://knowledge.broadcom.com/external/article?articleId=242825