The value of launchvar is not displayed in UVC when using uxadd FLA with parameter SES, UPR and MU
Reproduction:
Launch the Task with:
uxadd fla SES=<SES> UPR=<UPR> MU=<MU> PDATE="<MM/DD/YYYY" USER=<USER> LAUNCHVAR="((VARA,ADDFLA))"
Check the launch in UVC > Job Runs, the job is in Event Wait. When you inspect the values of VARA in UVC by opening the launch you will see the incorrect value VARA=UPR and Origin is empty.
In contrast, when you check the launch in the command line:
uxshw fla NSEQ=<Launch num> SES=* UPR=* MU=* you find the correct value VARA=ADDFLA
In DUAS v5 this worked correctly.
Release : 6.10
Component : DOLLAR UNIVERSE
Defect
Solution:
Update to a fix version listed below or a newer version if available.
Fix version:
Component(s): Application Server
Dollar.Universe v6.10.101 - Available