Below Cisco Environmental Alarms are not showing in spectrum,
1. Physical entity Alarm
2.CPU utilization
3.Temprature utilization
4.Memory utilization
Release : 21.2
Component :
This ip did not appear in the alert manager debug which means that this ip did not send any alert to Spectrum.
You need to discuss with the device owner why or with Cisco why these traps are not being sent to Spectrum e.g.
These alarms contained in the Cisco-ENVMON-mib.
The customer will ask Cisco, which mib the environmental traps and functionality is defined in. If it is not the ENVMON mib that we looked at, please get the correct mib from them and we can import it.
We need to enable alarms for the events in red. This is done from the OC console - tools tab - utilities - event configuration.
When the interface opens, filter on the event on the bottom left - marked in yellow below. Then on the alarm tab (in yellow) change the alarm severity to what you wish. Currently NONE means no alarm is sent for this event.
Save via the floppy disk image on the top right in red below