oi_connector not syncing all alarms from UIM to OI
search cancel

oi_connector not syncing all alarms from UIM to OI

book

Article ID: 249248

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

UIM - 20.4 
OI Connector -  1.44
OI On-Prem 21.31

UIM alarm counts in OI and UIM fall out of sync.  Specifically the alarm counts in UIM Operator Console are greater than the alarm counts in OI.  

Environment

Release : 20.4

Component : UIM - OI_CONNECTOR

Cause

Only some alarms are being processed by the oi_connector probe.

Resolution

After applying the oi_connector 1.45T3 probe and setting the following keys in the probe raw config, the issue was resolved.

process_open_uim_alarms = true
ingest_raw_alarm_to_oi = true

This version of the probe is attached to this article.

Attachments

oi_connector1.45T3_1666381112645.zip get_app