Unable to Repair ITMS. Error: Failed to construct DatabaseContext object. Connection to database failed.
book
Article ID: 248912
calendar_today
Updated On: 10-25-2024
Products
Asset Management Suite
Client Management Suite
IT Management Suite
Server Management Suite
Issue/Introduction
When attempting a repair, the following error occurred:
A critical error occurred:
Altiris.NS.Exceptions.DatabaseNotReadyException: Failed to construct DatabaseContext object. Connection to database failed.
Login failed. The login is from an untrusted domain and cannot be used with integrated authentication.
Cause
Authentication error when accessing the database during repair.
Resolution
Note: For any repair or upgrade, ensure that you log into the Notification Server with the Application Identity (Service) account.
- Using the Symantec Installation Manager, click the Configure Settings link.
- Click Configure Database Settings to set it to bold if it is not already bold and then click Next.
- Ensure the SQL server name and Database selection is correct, and click the Refresh button.
- If there are any warnings, these need to be addressed.
- In this case, switching from Windows Authentication to Use SQL Server login corrected the issue.