Tips on resolving SC03 abends in VISION:Results.
search cancel

Tips on resolving SC03 abends in VISION:Results.

book

Article ID: 24835

calendar_today

Updated On:

Products

Vision:Results

Issue/Introduction

How to resolve SC03 abends in VISION:Results.

Resolution

If you encounter an SC03 abend, there are multiple paths to pursue.

There are a few patches to resolve problems within the product:

SC03 abends on RESTORE programs frozen prior to release 5.0 are addressed by PTFs QO91585 and QO99458 which display on the Default Options page as 60025 and 60040. Remember that all release 6.0 PTFs have all prior PTFs as prerequisites.

If your maintenance is up to date, then examine the application.

  • Verify the LRECL and BLOCKSIZE values on FILE statements for input files match the DCB or leave them off and let VISION:Results acquire them from the operating system.

  • Verify the DCB values for output files on the FILE statement match the DCB. You can also allowing the system to determine the block size by adding the parameter SYSBLOCK to your OPTION statement if your site DYLINSTL parameter SYSBLOK is set to N.

  • Examine the application to verify a field does not access a field past the end of a record as this may have corrupted a DCB. This can happen when the record format is variable and logic branches depend upon input conditions and input is invalid.