Error Message TT110E request failed RC=17 under Thread Terminator
search cancel

Error Message TT110E request failed RC=17 under Thread Terminator

book

Article ID: 24817

calendar_today

Updated On:

Products

Thread Terminator for DB2 for z/OS

Issue/Introduction

When calling Thread Terminator for Db2 for z/OS (PTT) from the Value Pack and then selecting
U  Update DB2 Parameters / Option 18=DDF and data sharing parameters receive the following error message:
TT110E Request failed with maximum RC= 17

This occurs if specifying a Db2 data sharing group name in the field: "DB2 SSID" instead a full qualified Db2 ssid/member.

Resolution

Thread Terminator does not support Data Sharing Group Attach Names in place of Db2 SSIDs.
Please specify the Db2 ssid/member name in this field instead of the data sharing group name.