Getting DBG85007W Messages in Data Collector
search cancel

Getting DBG85007W Messages in Data Collector

book

Article ID: 247327

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS Database Management for DB2 for z/OS - Administration Suite Database Management for DB2 for z/OS - Performance Suite Database Management for DB2 for z/OS - Recovery Suite Database Management for DB2 for z/OS - SQL Performance Suite Database Management for DB2 for z/OS - Utilities Suite

Issue/Introduction

Multiple DBG85007W messages displayed in multiple Data Collectors. 

DBG85007W DB91 05:00:44 Unable to connect to CCS Data Mover: RC: 00000008, RSN: 00000004. 

What CCS Data Mover is.  Is it part of Sysview for DB2(IDB2)?

 

 

Environment

Release : 20.0

Component : SYSVIEW Performance Management Option for DB2 for z/OS

Resolution

Multiple DBG85007W messages displayed in multiple Data Collectors. 

CCS Data Mover is part of MOI(Mainframe Operational Intelligence) which can be integrated with IDB2. The integration is controlled by sysparm IQL-DEFINE=(MOI=YES). The following link provide details on how to do it:  If you do not intend to integrate MOI, then comment out the above parm in the IDDCPRMS and stop these IQL requests:

https://techdocs.broadcom.com/us/en/ca-mainframe-software/database-management/ca-sysview-performance-management-option-for-db2/20-0/configuring/integration-with-other-products/ca-mainframe-operational-intelligence-integration.html

If you do not intend to integrate MOI, then comment out the above parm in the IDDCPRMS and stop these IQL requests:

-IQLMDCPU: Collects CPU metrics

-IQLMSTAT: Collects Subsystem metrics

-IQLMBUFP: Collects Bufferpool metrics

-IQLMCCPU: Collects Connection metrics.