Running Ideal batch job IDBATCH gets errors:
IDADIDIN93D - INTERR: IDEAL INSTALLATION ERROR.
IDADIDIN92D - IDEAL REQUIRES PMS RELEASE 150 , FOUND RELEASE "140 "
All datasets that needed to be upgraded to 15.1 were upgraded as part of the ILCUS03 job.
What is this "PMS" component?
Release : 15.1
Component : Ideal
PMS is one of the IPC components, the PANEL MANAGEMENT SYSTEM.
The IDADIDIN92 message description says:
Ideal for Datacom initialization processing determined that the installed release of a supporting product or software component cannot be used with the current release of Ideal. The specified component release number, identified by "old-release-id" must be at the release level given by "new-release-id".
Action:
Review the libraries used to execute Ideal for Datacom and ensure that they contain the correct software.
This means it found the software for the PMS component is at release 14.0.
Check the STEPLIB in the Ideal batch job and ensure the CAVQLOAD loadlib is pointing to the new 15.1 dataset not the 14.0 one.
If there is no STEPLIB then check the LINKLIST is pointing to the new release CAVQLOAD.