Apply of Detector Hiper PTF fails with NOGO on prerequisites due to DYNACT ++HOLD action.
search cancel

Apply of Detector Hiper PTF fails with NOGO on prerequisites due to DYNACT ++HOLD action.

book

Article ID: 246693

calendar_today

Updated On:

Products

Detector for DB2 for z/OS

Issue/Introduction

The application of Detector for Db2 for z/OS (PDT) Hiper PTF LU06596 fails due to a prerequisite encountering a status of NOGO.

 

Environment

Release : 20.0
Component : Detector for DB2 for z/OS

Cause

The HOLDDATA type of DYNACT was specified for one of the PREREQ PTFs but the APPLY BYPASS HOLDSYSTEM parameter did not specify
DYNACT as one of the reasons to bypass.

Resolution

The APPLY was failing due to PTF HOLDDATA reason type of DYNACT.  The BYPASS(HOLDSYSTEM(xxxx,xxxx...) did not specify DYNACT
 as a reason thus the hold action was not resolved causing the APPLY failure. 

To correct the problem add DYNACT to the HOLDSYSTEM list on the BYPASS.
Specifying BYPASS(HOLDSYSTEM) without explicit reasons would also prove corrective.