Db2 tools Post Install ssid0000 Compare job fails with RMA209E error following FL506 Activation.
search cancel

Db2 tools Post Install ssid0000 Compare job fails with RMA209E error following FL506 Activation.

book

Article ID: 246432

calendar_today

Updated On:

Products

Database Management for DB2 for z/OS - Administration Suite Database Management for DB2 for z/OS - Performance Suite Database Management for DB2 for z/OS - Recovery Suite Database Management for DB2 for z/OS - SQL Performance Suite Database Management for DB2 for z/OS - Utilities Suite DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS

Issue/Introduction

The Database Management for Db2 for z/OS Post Install Compare ssid0000 job fails with the following 
error within the COMPRT step:

RMA209E ALL UNLOAD UTILITY MODELS EXCLUDED, NO UNLOADS GENERATED  
      RC/MIGRATOR ANALYSIS TERMINATING

Resolution

The RMA209E error was caused by an incorrect allocation of an obsolete RMMODTXT
model allocated on the //QIMODTXT DD within the COMPRT and DDLCOMP steps.


Make certain the allocation within the Post Install Compare, ssid0000, 
JCL for the COMPRT and DDLCOMP steps are:

//QIMODTXT DD  DISP=SHR,                                 
//             DSN=hlq.CDBASAMP(RMMODTXT)  


The correct allocation is resolved from the hlq.CDBAPARM DSNAMExx member
SRCLIB entry.  The SRCLIB entry within the DSNAMExx member for the Db2 
Tools r20 release should point to hlq.CDBASAMP.

Example: (SRCLIB   (hlq.CDBASAMP)