View - Want to stop generating DUPLEX tapes
search cancel

View - Want to stop generating DUPLEX tapes

book

Article ID: 245762

calendar_today

Updated On:

Products

View

Issue/Introduction

Our View started task creates duplex tapes. Is it possible to turn off Duplex tapes?

Environment

Release : View 14.0

Resolution

The (unit2-name) sub-parameter of the SARINIT "STORGRPn" parameters (STORGRPn=.../.../nnnnn/unit1-name,unit2-name/), determines whether tape duplexing is done by View.

To stop tape duplexing, change the parameter by removing the (unit2-name).

 . Remove "unit2-name" in the STORGRPn parameters.

 . Recycle the SARSTC task for the change(s) to take effect.

Once SARSTC is recycled with the changes, the View backups and SARPAC will no longer create a duplex tape.

When a primary tape expires, the duplex tape will expire as well, as the primary and duplex tapes are exact images.

If the duplex tapes are to be expired, it would need to be done manually with the SARDPLX tapes being uncataloged and scratched.

For additional information on the View STORGRPn parameters, see the following area of documentation, starting with the STORGRP0 parameter specifically:

Initialization Parameter Statements