OAM getting S0C4 abend in SMS IGDZILLA IGDCNSMV +49E
search cancel

OAM getting S0C4 abend in SMS IGDZILLA IGDCNSMV +49E

book

Article ID: 245547

calendar_today

Updated On:

Products

Datacom/DB

Issue/Introduction

Running a Datacom Online Area Move (OAM) against the IXX and data area.

The job appears to have worked but there were S0C4 abends reported in IGDCNSMV +49E.

The abends occur when Datacom is doing the rename of files.

 19.48.34 JOB22956  IGD300I AN ABEND OCCURRED DURING SMS PROCESSING  504
    504               ABEND SYSTEM CODE=0C4 ASID=00A9
    504               COMPONENT NAME=SMS  COMPONENT ID=DF101
    504               ACTIVE LOAD MODULE  NAME=IGDZILLA ADDRESS=07CDE000
    504               CSECT IN ERROR      DESCRIPTION=MOV USER A.S.DATA
    504                                   NAME=IGDCNSMV ADDRESS=07CFE858 OFFSET=0000049E
    504                                   ASSEMBLY DATE=031017   PTF LEVEL=HDZ2230
    504               PSW AT TIME OF ERROR 070C0000 87CFECF6
    504               DATA AT PSW 07CFECF0 - B04C4160 0100DA32 40005000
    504               GPR 00-03  00000009  7E7A4EBC  00000000  000000A0
    504               GPR 04-07  7E7A2644  C7D9D740  00000100  00000000
    504               GPR 08-11  0098A378  7E7A3217  07CEE4B0  7E7A4E40
    504               GPR 12-15  87CFE8AC  7E7A4E40  87CFE982  00000000

Environment

Release : 15.1

Component : DATACOM/DB

Cause

It was found the S0C4 was also occurring when a rename of a dataset on an SMS controlled volume was performed in TSO.  

This is an IBM z/OS problem.

Resolution

No specific IBM PTF was found for z/OS 2.3. The problem did not occur after upgrading to z/OS 2.5.