MacKinney DBLC fails to OPEN a DB URT but MBCE137 message has no RC
search cancel

MacKinney DBLC fails to OPEN a DB URT but MBCE137 message has no RC

book

Article ID: 244920

calendar_today

Updated On:

Products

Datacom Datacom/DB

Issue/Introduction

Trying to open, via a MacKinney Batch to CICS job, a Datacom URT on a CICS region where there is no PPT for that URT program.

The OPEN obviously fails, but the DB Return Code passed by the MacKinney error message is blank:

 DBLC OPEN=086                                                             <ERR   06/16/22 00:36:04 MBCRXDPL 2.1 USZAPK4 
 MBCE137-COMMAND DBLC OPEN=086  WAS UNSUCCESSFUL RC(  )                           06/16/22 00:36:04 MBCRXDPL 2.1 USZAPK4 
 DBLC OPEN=086                                                             <FLSH  06/16/22 00:36:04 MBCRZIN  2.1 USZAPK4   


MacKinney support states that they are simply displaying the Return Code returned by Datacom.

Environment

Release : 15.1

Component : DATACOM CICS SERVICES

Resolution

When a URT has no PPT entry, the error message (DC00202I  URT nnnn-mmmm HAVE NO CSD ENTRIES) is returned by Datacom CICS Services before Datacom could issue the OPEN, so there is no Datacom Return Code.