OPSPARM SHOW command results in RC 112
search cancel

OPSPARM SHOW command results in RC 112

book

Article ID: 244665

calendar_today

Updated On:

Products

OPS/MVS Event Management & Automation

Issue/Introduction

I am receiving a RC112 from an OPSPARM SHOW command, getting the following message: CURRENT RELEASE CODE '12.03.00' ¬= OPSS RELEASE CODE 13.05.00

Explanation of RC112 -

112

n/a

MASTER/LOCAL VERSION CODE MISMATCH

OPSS is at 13.05.00.

Could you direct me where to look for the mismatch of version code? 

Environment

Release : 13.5

Component : OPS/MVS

Cause

This problem most often occurs after a product upgrade, where a load library containing modules from the previous release is concatenated ahead of the libraries associated with the new release in the search order.

Resolution

Ensure that the correct load modules for the intended OPS/MVS product release are found first in the search order for all related OPS/MVS started tasks and servers, such as OPSMAIN, OSF, USS, etc.., and also any TSO procs used for accessing OPS/MVS. 

Additional Information

OPSPARM Command Processor documentation:

OPSPARM Command Processor