Issue/Introduction

UIM 20.4 with MS SQL Server as the backend database with a connection to UIM Database using windows authentication.

We deployed 'UIM Server 20.4 - Cumulative Update 3' and now Admin Console login fails:

wasp log error captured on startup

ERROR [main, com.nimsoft.nimbus.probe.service.wasp.Probe] doit() Failed to createDataSource
ERROR [main, com.nimsoft.nimbus.probe.service.wasp.Probe] com.microsoft.sqlserver.jdbc.SQLServerException: This driver is not configured for integrated authentication. ClientConnectionId:5a079731-8d31-4d18-bac7-b171f80b7cd0
 at com.microsoft.sqlserver.jdbc.SQLServerConnection.terminate(SQLServerConnection.java:3422)

Environment

Release : 20.4

Component :UIM - UMP_ADMINCONSOLE2

Cause

java_jre 2.13 was not installed per CU3 requirement

Resolution

Deploy java_jre 2.13 to the Primary Hub robot per steps in 'UIM Server 20.4 - Cumulative Update 3'